Wednesday, August 07, 2019

Engr. Aneel Kumar

ELEMENTS OF MEASUREMENT SYSTEM

I) PRIMARY SENSING ELEMENT


This is the element that first receives energy from the measured medium and procedures an output depending on some way on the measured quantity (measured). 

The output is some physical variable e.g. displacement or voltage. An instrument always extract some energy from the measured medium. The measured quantity is always disturbed by the act of measurement, which makes a perfect theoretically impossible. Good instruments are designed to minimize this loading effect. 

II) VARIABLE CONVERSION ELEMENT


If may be necessary to convert the output signal of the primary sensing element to another more suitable variable while preserving the information content of the original signal. This element performs this function. 

III) VARIABLE MANIPULATION ELEMENT


An instrument may require that a signal represented by some physical variable be manipulated by some way. 

By manipulation we mean specifically a change in numerical value according to some definite rule but a preservation of the physical nature of the variable. This element performs such a function. 

IV) DATA-TRANSMISSION ELEMENT


When functional elements of an instrument are actually physically separated, it becomes necessary to transmit the data from one to another. This element performs this function. 

V) DATA PRESENTATION ELEMENT


If the information about the measured quantity is to be communicated to a human being for monitoring, control, or analysis purposes, it must be put into a form recognizable by one of the human senses. This element performs this ‘translation’ function. 

VI) DATA STORAGE/PLAYBACK ELEMENT


Some applications require a distinct data storage/playback which can easily recreate the stored data upon command.
Read More
Engr. Aneel Kumar

TYPES OF ELECTRICAL LOADS

Resistive Load


Resistive loads can be purely resistive or of the tungsten-heater load type. A resistive load that has no heating element is the easiest for a switch to handle, and the switch’s rating is based on this type of load. A resistive load is one in which 100% of the load is composed of resistive devices. The power factor is high (PF = 1) and contact erosion is low. Consequently, the switch’s electrical life can be anticipated with some certainty. 

Lamp Load


When a switch closes on a resistive lamp load, the switch sees a short circuit because the cold resistance of the lamp filament is near zero. The surge current as the switch closes can be many times the steady state current. As the lamp filament heats up to operating temperature, the resistance of the filament increases and the current decreases to the lamp’s steady state. 

Motor


Motor loads present yet another brutal environment for switch contacts. Closing the switch contact on a motor start-up load causes very large current surges of about 3 to 8 times the running current. When the switch is opened and the current decreases, the magnetic field of the inductor collapses and an electromotive force is induced. The polarity of the induced voltage is such as to oppose any change in current flow. This induced voltage aids the source voltage in striking an arc and maintaining it as the contacts separate. 

Inductive Load


Non-motor inductive loads, such as those seen in switching power supplies, have inrush currents that greatly exceed the normal operating currents of the equipment. This inrush current can easily reach 8 to 10 times the steady state current. As a switch on an inductive load is opened, the inductor, or transformer, induces a counter option “voltage” in the circuit. This voltage opposes any change in the circuit current and can reach hundreds of volts. This extremely high voltage can restrike the arc as the switch contacts open resulting in severely eroded or welded contacts. 

Capacitive


With such loads as DC power supplies, welding machines, and strobe charging units the inrush current is even more damaging than with inductive loads. To the switch a capacitive load appears as a dead short as the switch closes. In the first few milliseconds the inrush current can sometimes reach 100 times the steady state current of the circuit. Even worse for the switch, this inrush occurs before the contact bounce has subsided. This produces severe arcing and massive contact erosion. Often the contacts weld upon closure preventing the switch from ever opening. In an emergency the operator of the equipment would know he could not open the circuit.
Read More