Friday, February 13, 2015

Engr. Aneel Kumar

FACTS SYSTEM CONTROLLER

SVC: Uses thyristor valves to rapidly add or remove shunt connected reactors and or capacitors often in coordination with mechanically controlled reactors and/or capacitors.

NGH-SSR DAMPER: a resonance damper, a thyristor ac-switch connected in series with a small inductor and resistor across the series capacitor.

STATCOM (static condenser): A 3 phase inverter that is driven from voltage across a dc storage capacitor and whose there output voltages are in phase with the ac system voltage. When the output voltages are higher or lower than the ac system voltage the current flow is caused to lead or lag and difference in voltage amplitudes determine how much current flows. Reactive power and its polarity can be controlled by controlling voltage.
PHASE ANGLE REGULATOR: The phase shift is accomplished by adding or subtracting a variable voltage concept that is perpendicular to the phase voltage of the line.

UNIFIED POWER CONTROL: In this concept an ac voltage vector generated by a thyristor based inverter is injected in series with phase voltage. The driving dc voltage for inverter is obtained by rectifying the ac to dc from the same transmission line. In such an arrangement the injected voltage may have any phase angle relationship to the phase voltage. It is possible to obtain a net phase and amplitude voltage change that confers control of both active and reactive power.

DYNAMIC BRAKE: A shunt connected resistive load, controlled by thyristor switches. such a load can be selectively applied in each pass, half cycle by half cycle to damp any specific power flow oscillation, so that generating unit run less risk of losing synchronism, as a result more can be transferred over systems subjected to stability constraints.

A thyristor controlled resistor in parallel with the transmission line can be used effectively to damp power swing oscillations in the transmission system. FACT technology ensures power flow through prescribed routes, maximization of capacity, securing loading capacity enhancement under various scenarios of uprating or upgrading the lines thermal current capacity. One of the important function of FACT is VAR compensation.

TYPES ATTRIBUTES
NGH- SSR Damper Damping of oscillation, series impedance control, transient stability
SVC-static var-compensator Voltage control, var-compensation damping of oscillation
TCSC-Thyristor controlled series capacitor Power control, voltage control, series impedance control, damping of oscillations, transient stability
Static-condensor Voltage control, VAR-compensator damping of oscillations, transient stability.
Thyristor controlled phase angle regulator Power control, voltage control, var-compensator, damping of oscillation, transient stability.
Thyristor controlled dynamic brake Damping of oscillation, transient stability.

Engr. Aneel Kumar -

Subscribe to this Blog via Email :