Skip to main content

Electrical Engineering Objective Type By M Handa

Electrical Engineering Objective Type By M. Handa & A. Handa



Index

  1. Electrical Current & Ohms Law
  2. Source of EMF
  3. AC Fundamentals
  4. RLC Circuits
  5. Network Theory
  6. Control System
  7. Engineering Materials
  8. Electrostatics
  9. Magneto Statics
  10. Electromagnetics
  11. Vacuum Tubes
  12. Semi-Conductors
  13. Transistors
  14. Amplifiers
  15. Oscillators
  16. Digital Electronics
  17. DC Generators
  18. DC Motors
  19. Transformers
  20. Synchronous Generators
  21. Synchronous Motors
  22. Induction Motors
  23. Single Phase Motors
  24. Generation of Electrical Power
  25. Economics of Power Generation
  26. Transmission & Distribution
  27. Circuit Breakers
  28. Transmission Lines & Cables
  29. High Voltage Engineering
  30. Rectifiers & Converters
  31. Illumination
  32. Electric Traction
  33. Heating & Welding
  34. Electrical Machine Design
  35. Industrial Drives
  36. Instruments & Measurement
  37. Power Electronics
  38. Computation
  39. Model Papers


Click here to download
Note: Use any proxy server if found 8 hours delay or any other error and change your location to USA, Germany, UK or any other.

Comments

Popular posts from this blog

ADVANTAGES AND DISADVANTAGES OF CORONA

Corona has many advantages and disadvantages. In the correct design of a high voltage overhead line, a balance should be struck between the advantages and disadvantages. ADVANTAGES (i) Due to corona formation, the air surrounding the conductor becomes conducting and hence virtual diameter of the conductor is increased. The increased diameter reduces the electrostatic stresses between the conductors. (ii) Corona reduces the effects of transients produced by surges. DIS-ADVANTAGES (i) Corona is accompanied by a loss of energy. This affects the transmission efficiency of the line. (ii) Ozone is produced by corona and may cause corrosion of the conductor due to chemical action. (iii) The current drawn by the line due to corona is non-sinusoidal and hence non-sinusoidal voltage drop occurs in the line. This may cause inductive interference with neighboring communication lines.

ADVANTAGES OF PER UNIT SYSTEM

PER UNIT SYSTEM The per-unit system expressed the voltages, currents, powers, impedances, and other electrical quantities basis by the equation: Quantity per unit (pu) = Actual value/ Base value of quantity ADVANTAGES OF PER UNIT SYSTEM While performing calculations, referring quantities from one side of the transformer to the other side serious errors may be committed. This can be avoided by using per unit system. Voltages, currents and impedances expressed in per unit do not change when they are referred from one side of transformer to the other side. This is a great advantage. Per unit impedances of electrical equipment of similar type usually lie within a narrow range, when the equipment ratings are used as base values. Transformer connections do not affect the per unit values. Manufacturers usually specify the impedances of machines and transformers in per unit or percent of name plate ratings. Transformers can be replaced by their equivalent series impedances. ...

ABSOLUTE AND SECONDARY INSTRUMENTS

The various electrical instruments may, in a very broad sense, be divided into (i) Absolute Instruments (ii) Secondary Instruments. Absolute Instruments are those which give the value of the quantity to be measured, in terms of the constants of the instrument and their deflection only. No previous calibration or comparison is necessary in their case. The example of such an instrument is tangent galvanometer, which gives the value of current, in terms of the tangent of deflection produced by the current, the radius and number of turns of wire used and the horizontal component of earth’s field.  Secondary Instruments  are those, in which the value of electrical quantity to be measured can be determined from the deflection of the instruments, only when they have been pre-calibrated by comparison with an absolute instrument. Without calibration, the deflection of such instruments is meaningless. It is the secondary instruments, which are most generally used in ev...